• Mon espace de travail
  • Aide IRIS
  • Par Publication Par Personne Par Unité
    • English
    • Français
  • Se connecter
Logo du site

IRIS | Système d’Information de la Recherche Institutionnelle

  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
UNIL
  • English
  • Français
Se connecter
IRIS
  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
  • Mon espace de travail
  • Aide IRIS

Parcourir IRIS

  • Par Publication
  • Par Personne
  • Par Unité
  1. Accueil
  2. IRIS
  3. Publication
  4. Descemet stripping endothelial keratoplasty for a failed penetrating keratoplasty graft in a pseudophakic patient with a toric intraocular lens: a case report.
 
  • Détails
Titre

Descemet stripping endothelial keratoplasty for a failed penetrating keratoplasty graft in a pseudophakic patient with a toric intraocular lens: a case report.

Type
étude de cas
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
BMC Ophthalmology  
Auteur(s)
Kymionis, G.D.
Auteure/Auteur
Kontadakis, G.A.
Auteure/Auteur
Liens vers les personnes
Kymionis, George  
Liens vers les unités
Hôpital ophtalmique Jules Gonin  
ISSN
1471-2415
Statut éditorial
Publié
Date de publication
2013-10-30
Volume
13
Première page
64
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Case Reports ; Journal Article
Publication Status: epublish
Résumé
To report a patient with penetrating keratoplasty (PKP) graft endothelial failure implanted with toric intraocular lens (IOL) who was treated with Descemet stripping endothelial keratoplasty (DSAEK).
A 40 year old male patient implanted with toric intraocular lens for the treatment of post PKP astigmatism, presented for the treatment of graft endothelial failure'. The patient had uncorrected distance visual acuity (UDVA) 20/200 not correcting with manifest refraction. The patient reported excellent visual acuity after cataract surgery and toric IOL implantation. DSAEK was performed in order to minimally affect keratometry and retain correspondence of the anterior cornea astigmatism with the toric IOL astigmatic power. Three months postoperatively the cornea was clear with no edema. UDVA was 20/40 and corrected distance visual acuity was 20/25 with +1.50-1.00 × 20.
This report describes a unique case of DSAEK for treatment of a failed PKP in a patient previously implanted with a toric IOL. DSAEK was an effective alternative of PKP in this patient for the preservation of the toric IOL's effect.
Sujets

Adult

Astigmatism/etiology

Astigmatism/surgery

Descemet Stripping En...

Humans

Keratoplasty, Penetra...

Lens Implantation, In...

Lenses, Intraocular

Male

Pseudophakia/complica...

Pseudophakia/surgery

Reoperation

Treatment Failure

PID Serval
serval:BIB_2025549C80CD
DOI
10.1186/1471-2415-13-64
PMID
24171843
WOS
000327489900001
Permalien
https://iris.unil.ch/handle/iris/77184
Open Access
Oui
Date de création
2019-10-01T11:55:17.752Z
Date de création dans IRIS
2025-05-20T16:48:31Z
Fichier(s)
En cours de chargement...
Vignette d'image
Nom

24171843_BIB_2025549C80CD.pdf

Version du manuscrit

published

Licence

https://creativecommons.org/licenses/by/4.0

Taille

1023.1 KB

Format

Adobe PDF

PID Serval

serval:BIB_2025549C80CD.P001

URN

urn:nbn:ch:serval-BIB_2025549C80CD6

Somme de contrôle

(MD5):03874ad62fb2379456eabe708d7e64ee

  • Copyright © 2024 UNIL
  • Informations légales