  4. Utilite du Remler pour eviter de surtraiter la population dite hypertendue. [Usefulness of the Remler device in avoiding overtreatment of the so-called hypertensive population]
 
  • Détails
Titre

Utilite du Remler pour eviter de surtraiter la population dite hypertendue. [Usefulness of the Remler device in avoiding overtreatment of the so-called hypertensive population]

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Schweizerische medizinische Wochenschrift  
Auteur(s)
Schaller , M. D.
Auteure/Auteur
Jacot des Combes , B.
Auteure/Auteur
Waeber, B.
Auteure/Auteur
Porchet, M.
Auteure/Auteur
Brunner , H. R.
Auteure/Auteur
Liens vers les personnes
Waeber, Bernard  
Liens vers les unités
Physiopathologie clinique  
ISSN
0036-7672
Statut éditorial
Publié
Date de publication
1983
Volume
113
Numéro
52
Première page
2004
Dernière page/numéro d’article
5
Peer-reviewed
Oui
Langue
français
Notes
Comparative Study
English Abstract
Journal Article
Résumé
To assess the reliability of the Remler system, a semi-automatic pressure recording device, several blood pressures were measured simultaneously by the conventional auscultatory method and by the Remler in 12 normotensive volunteers. In all situations tested both the Remler and auscultatory blood pressures were very close, thus demonstrating the reliability of this new technique. Ambulatory blood pressure recordings were then obtained with the Remler in 245 untreated patients referred for hypertension by their private physicians. Surprisingly, in close to 60% of them the average of all blood pressures recorded during usual activities was within the normal range. Since cardiovascular complications seem to correlate better with ambulatory than with office blood pressure levels, the Remler system appears particularly useful in recognizing those patients who, although hypertensive in the physician's office, remain normotensive during the day and therefore may not require antihypertensive treatment.
Sujets

Activities of Daily L...

PID Serval
serval:BIB_FE0B28640A6A
PMID
6665543
WOS
A1983RX03400004
Permalien
https://iris.unil.ch/handle/iris/257510
Date de création
2009-03-06T11:00:42.727Z
Date de création dans IRIS
2025-05-21T07:10:13Z
  • Copyright © 2024 UNIL