• Mon espace de travail
  • Aide IRIS
  • Par Publication Par Personne Par Unité
    • English
    • Français
  • Se connecter
Logo du site

IRIS | Système d’Information de la Recherche Institutionnelle

  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
UNIL
  • English
  • Français
Se connecter
IRIS
  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
  • Mon espace de travail
  • Aide IRIS

Parcourir IRIS

  • Par Publication
  • Par Personne
  • Par Unité
  1. Accueil
  2. IRIS
  3. Publication
  4. IMRT credentialing for prospective trials using institutional virtual phantoms: results of a joint European Organization for the Research and Treatment of Cancer and Radiological Physics Center project.
 
  • Détails
Titre

IMRT credentialing for prospective trials using institutional virtual phantoms: results of a joint European Organization for the Research and Treatment of Cancer and Radiological Physics Center project.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Radiation Oncology  
Auteur(s)
Weber, D.C.
Auteure/Auteur
Vallet, V.
Auteure/Auteur
Molineu, A.
Auteure/Auteur
Melidis, C.
Auteure/Auteur
Teglas, V.
Auteure/Auteur
Naudy, S.
Auteure/Auteur
Moeckli, R.
Auteure/Auteur
Followill, D.S.
Auteure/Auteur
Hurkmans, C.W.
Auteure/Auteur
Liens vers les personnes
Moeckli, Raphaël  
Liens vers les unités
Radiophysique  
ISSN
1748-717X
Statut éditorial
Publié
Date de publication
2014
Volume
9
Numéro
1
Première page
123
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article Publication Status: epublish PDF : research
Résumé
BACKGROUND AND PURPOSE: Intensity-modulated radiotherapy (IMRT) credentialing for a EORTC study was performed using an anthropomorphic head phantom from the Radiological Physics Center (RPC; RPCPH). Institutions were retrospectively requested to irradiate their institutional phantom (INSTPH) using the same treatment plan in the framework of a Virtual Phantom Project (VPP) for IMRT credentialing.
MATERIALS AND METHODS: CT data set of the institutional phantom and measured 2D dose matrices were requested from centers and sent to a dedicated secure EORTC uploader. Data from the RPCPH and INSTPH were thereafter centrally analyzed and inter-compared by the QA team using commercially available software (RIT; ver.5.2; Colorado Springs, USA).
RESULTS: Eighteen institutions participated to the VPP. The measurements of 6 (33%) institutions could not be analyzed centrally. All other centers passed both the VPP and the RPC ±7%/4 mm credentialing criteria. At the 5%/5 mm gamma criteria (90% of pixels passing), 11(92%) as compared to 12 (100%) centers pass the credentialing process with RPCPH and INSTPH (p = 0.29), respectively. The corresponding pass rate for the 3%/3 mm gamma criteria (90% of pixels passing) was 2 (17%) and 9 (75%; p = 0.01), respectively.
CONCLUSIONS: IMRT dosimetry gamma evaluations in a single plane for a H&N prospective trial using the INSTPH measurements showed agreement at the gamma index criteria of ±5%/5 mm (90% of pixels passing) for a small number of VPP measurements. Using more stringent, criteria, the RPCPH and INSTPH comparison showed disagreement. More data is warranted and urgently required within the framework of prospective studies.
PID Serval
serval:BIB_C486EBC09E7E
DOI
10.1186/1748-717X-9-123
PMID
24885438
WOS
000336938000001
Permalien
https://iris.unil.ch/handle/iris/211192
Open Access
Oui
Date de création
2014-07-04T15:48:27.270Z
Date de création dans IRIS
2025-05-21T03:32:26Z
Fichier(s)
En cours de chargement...
Vignette d'image
Nom

BIB_C486EBC09E7E.P001.pdf

Version du manuscrit

preprint

Taille

337.96 KB

Format

Adobe PDF

PID Serval

serval:BIB_C486EBC09E7E.P001

URN

urn:nbn:ch:serval-BIB_C486EBC09E7E8

Somme de contrôle

(MD5):85a20a61c80a96817da16410bbb6fce2

  • Copyright © 2024 UNIL
  • Informations légales