  4. The Smartcanula: a new tool for remote access perfusion in limited access cardiac surgery.
 
  • Détails
Titre

The Smartcanula: a new tool for remote access perfusion in limited access cardiac surgery.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Heart Surgery Forum
Auteur(s)
von Segesser, L.K.
Auteure/Auteur
Jegger, D.
Auteure/Auteur
Mucciolo, G.
Auteure/Auteur
Tozzi, P.
Auteure/Auteur
Mucciolo, A.
Auteure/Auteur
Delay, D.
Auteure/Auteur
Mallabiabarrena, I.
Auteure/Auteur
Horisberger, J.
Auteure/Auteur
Liens vers les personnes
Jegger, David  
Delay, Dominique  
Tozzi, Piergiorgio  
Von Segesser, Ludwig Karl  
Liens vers les unités
Chirurgie cardiaque  
ISSN
1522-6662[electronic]
Statut éditorial
Publié
Date de publication
2005
Volume
8
Numéro
4
Première page
E241
Dernière page/numéro d’article
E245
Langue
anglais
Notes
Publication types: Journal Article
Résumé
Devices for venous cannulation have seen significant progress over time: the original, rigid steel cannulas have evolved toward flexible plastic cannulas with wire support that prevents kinking, very thin walled wire wound cannulas allowing for percutaneous application, and all sorts of combinations. In contrast to all these rectilinear venous cannula designs, which present the same cross-sectional area over their entire intravascular path, the smartcanula concept of "collapsed insertion and expansion in situ" is the logical next step for venous access. Automatically adjusting cross-sectional area up to a pre-determined diameter or the vessel lumen provides optimal flow and ease of use for both, insertion and removal. Smartcanula performance was assessed in a small series of patients (76 +/- 17 kg) undergoing redo procedures. The calculated target pump flow (2.4 L/min/m2) was 4.42 +/- 61 L/ min. Mean pump flow achieved during cardiopulmonary bypass was 4.84 +/- 87 L/min or 110% of the target. Reduced atrial chatter, kink resistance in situ, and improved blood drainage despite smaller access orifice size, are the most striking advantages of this new device. The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective.
Sujets

Cardiac Surgical Proc...

Cardiopulmonary Bypas...

Catheterization

Female

Humans

Male

Middle Aged

Perfusion

PID Serval
serval:BIB_5B33E85CA737
DOI
10.1532/HSF98.20051127
PMID
16112936
WOS
000233336600010
Permalien
https://iris.unil.ch/handle/iris/99481
Date de création
2008-01-28T08:28:45.151Z
Date de création dans IRIS
2025-05-20T18:31:35Z
  • Copyright © 2024 UNIL
  • Informations légales