• Mon espace de travail
  • Aide IRIS
  • Par Publication Par Personne Par Unité
    • English
    • Français
  • Se connecter
Logo du site

IRIS | Système d’Information de la Recherche Institutionnelle

  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
UNIL
  • English
  • Français
Se connecter
IRIS
  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
  • Mon espace de travail
  • Aide IRIS

Parcourir IRIS

  • Par Publication
  • Par Personne
  • Par Unité
  1. Accueil
  2. IRIS
  3. Publication
  4. Ultrasound-based Measurement of the Intra-scaphoid angle.
 
  • Détails
Titre

Ultrasound-based Measurement of the Intra-scaphoid angle.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Hand Surgery and Rehabilitation  
Auteur(s)
Maniglio, M.
Auteure/Auteur
Moutinot, B.
Auteure/Auteur
Durand, S.
Auteure/Auteur
Liens vers les personnes
Durand, Sébastien  
Liens vers les unités
Chir. plast. reconstr. esthét.&main  
ISSN
2468-1210
Statut éditorial
Publié
Date de publication
2024-10
Volume
43
Numéro
5
Première page
101755
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Ultrasound is gaining popularity for diagnosing scaphoid fractures. However, it hasn't been used to assess fracture displacement, such as humpback deformity. We propose a sonographic method to measure the intra-scaphoid angle, potentially serving as an alternative to CT scans for detecting fragment malposition after a scaphoid fracture.
We recruited 11 healthy adult volunteers without wrist pathology and performed bilateral wrist ultrasounds, totaling 22 examinations. Each wrist was splinted at 50 ° extension and fully supinated. Two hand surgeons independently performed the ultrasounds. All images were then evaluated separately by two evaluators. The following measurements were taken: 1. Inter-poles distance (IPD): Distance between the summits of the two scaphoid poles on the palmar cortex. 2. Palmar cortical intra-scaphoid angle (PCISA): Angle between the two summits and the deepest point of the waist on the palmar cortex. Measurements were compared for inter-investigator and inter-evaluator reliability using the intraclass correlation coefficient (ICC).
The study included four males and seven females, with an average age of 35 years (range 21-56). The mean PCISA was 142 ° (SD 10 °) and the mean IPD was 16.3 mm (SD 2.1 mm). Differences in IPD measurements averaged 0.3 mm (range 0-5.2 mm) among investigators and 1.0 mm (range 0.1-3.8 mm) among evaluators. For PCISA, the differences averaged 4 ° (range 0-17 °) among investigators and 6 ° (range 0-15 °) among evaluators. The ICC for IPD was 0.804 (investigators) and 0.572 (evaluators); for PCISA, it was 0.704 (investigators) and 0.602 (evaluators).
This study presents a cost-effective and accessible sonographic technique to measure the intra-scaphoid angle. Further research is required to assess its effectiveness in scaphoid fractures and compare it to CT-based measurements like the H/L ratio, LISA, and DCA.
Sujets

Humans

Male

Female

Adult

Ultrasonography

Scaphoid Bone/diagnos...

Scaphoid Bone/injurie...

Middle Aged

Young Adult

Healthy Volunteers

Reproducibility of Re...

Diagnostic accuracy

Humpback deformity

Scaphoid

Scaphoid fracture

Scaphoid non-union

Sonographic measureme...

Ultrasound

PID Serval
serval:BIB_C95CE58D048F
DOI
10.1016/j.hansur.2024.101755
PMID
39117061
WOS
001354959200001
Permalien
https://iris.unil.ch/handle/iris/205551
Open Access
Oui
Date de création
2024-08-16T13:28:15.910Z
Date de création dans IRIS
2025-05-21T03:02:34Z
Fichier(s)
En cours de chargement...
Vignette d'image
Nom

39117061.pdf

Version du manuscrit

published

Licence

https://creativecommons.org/licenses/by/4.0

Taille

1.01 MB

Format

Adobe PDF

PID Serval

serval:BIB_C95CE58D048F.P001

URN

urn:nbn:ch:serval-BIB_C95CE58D048F1

Somme de contrôle

(MD5):97314fd4e3aa72f45922a98c6358970b

  • Copyright © 2024 UNIL
  • Informations légales