Titre
Stent by stent crush: procedural outcome and angiographic follow-up
Type
étude de cas
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Catheterization and Cardiovascular Diagnosis
Auteur(s)
Eeckhout, E.
Auteure/Auteur
Vogt, P.
Auteure/Auteur
Liens vers les personnes
Liens vers les unités
ISSN
0098-6569
Statut éditorial
Publié
Date de publication
1998-09
Volume
45
Numéro
1
Première page
54
Dernière page/numéro d’article
6
Notes
Case Reports
Journal Article --- Old month value: Sep
Journal Article --- Old month value: Sep
Résumé
Rewiring of an occluded and incompletely deployed coronary stent with a sharp and/or tortuous entrance angle may be difficult in the emergency setting. We report the case of a patient who experienced subacute stent thrombosis in the proximal right coronary artery. Incorrect rewiring resulted in stent crush after conventional balloon angioplasty at lesion site. In order to improve the angiographic result parallel stent placement was performed. Repeat angiography at 6 months demonstrated vessel patency without restenosis.