  4. Recommendations to reduce hand exposure for standard nuclear medicine procedures
 
  • Détails
Titre

Recommendations to reduce hand exposure for standard nuclear medicine procedures

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Radiation Measurements  
Auteur(s)
Sans-Merce, M.
Auteure/Auteur
Ruiz, N.
Auteure/Auteur
Barth, I.
Auteure/Auteur
Carnicer, A.
Auteure/Auteur
Donadille, L.
Auteure/Auteur
Ferrari, P.
Auteure/Auteur
Fulop, M.
Auteure/Auteur
Ginjaume, M.
Auteure/Auteur
Gualdrini, G.
Auteure/Auteur
Krim, S.
Auteure/Auteur
Mariotti, F.
Auteure/Auteur
Ortega, X.
Auteure/Auteur
Rimpler, A.
Auteure/Auteur
Vanhavere, F.
Auteure/Auteur
Baechler, S.
Auteure/Auteur
Liens vers les personnes
Baechler, Sebastien  
Sans Merce , Marta  
Liens vers les unités
Radiophysique  
ISSN
1350-4487
Statut éditorial
Publié
Date de publication
2011
Volume
46
Numéro
11
Première page
1330
Dernière page/numéro d’article
1333
Langue
anglais
Résumé
The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.
PID Serval
serval:BIB_9C6897C4B71E
DOI
10.1016/j.radmeas.2011.07.011