New electrocardiographic criteria for discriminating between Brugada types 2 and 3 patterns and incomplete right bundle branch block.
Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Auteur(s)
Chevallier, S.
Auteure/Auteur
Forclaz, A.
Auteure/Auteur
Tenkorang, J.
Auteure/Auteur
Ahmad, Y.
Auteure/Auteur
Faouzi, M.
Auteure/Auteur
Graf, D.
Auteure/Auteur
Schlaepfer, J.
Auteure/Auteur
Pruvot, E.
Auteure/Auteur
Liens vers les personnes
Liens vers les unités
ISSN
1558-3597
Statut éditorial
Publié
Date de publication
2011
Volume
58
Numéro
22
Première page
2290
Dernière page/numéro d’article
2298
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Publication Status: ppublish
Résumé
OBJECTIVES: The aim of this study was to evaluate new electrocardiographic (ECG) criteria for discriminating between incomplete right bundle branch block (RBBB) and the Brugada types 2 and 3 ECG patterns.
BACKGROUND: Brugada syndrome can manifest as either type 2 or type 3 pattern. The latter should be distinguished from incomplete RBBB, present in 3% of the population.
METHODS: Thirty-eight patients with either type 2 or type 3 Brugada pattern that were referred for an antiarrhythmic drug challenge (AAD) were included. Before AAD, 2 angles were measured from ECG leads V(1) and/or V(2) showing incomplete RBBB: 1) α, the angle between a vertical line and the downslope of the r'-wave, and 2) β, the angle between the upslope of the S-wave and the downslope of the r'-wave. Baseline angle values, alone or combined with QRS duration, were compared between patients with negative and positive results on AAD. Receiver-operating characteristic curves were constructed to identify optimal discriminative cutoff values.
RESULTS: The mean β angle was significantly smaller in the 14 patients with negative results on AAD compared to the 24 patients with positive results on AAD (36 ± 20° vs. 62 ± 20°, p < 0.01). Its optimal cutoff value was 58°, which yielded a positive predictive value of 73% and a negative predictive value of 87% for conversion to type 1 pattern on AAD; α was slightly less sensitive and specific compared with β. When the angles were combined with QRS duration, it tended to improve discrimination.
CONCLUSIONS: In patients with suspected Brugada syndrome, simple ECG criteria can enable discrimination between incomplete RBBB and types 2 and 3 Brugada patterns.
BACKGROUND: Brugada syndrome can manifest as either type 2 or type 3 pattern. The latter should be distinguished from incomplete RBBB, present in 3% of the population.
METHODS: Thirty-eight patients with either type 2 or type 3 Brugada pattern that were referred for an antiarrhythmic drug challenge (AAD) were included. Before AAD, 2 angles were measured from ECG leads V(1) and/or V(2) showing incomplete RBBB: 1) α, the angle between a vertical line and the downslope of the r'-wave, and 2) β, the angle between the upslope of the S-wave and the downslope of the r'-wave. Baseline angle values, alone or combined with QRS duration, were compared between patients with negative and positive results on AAD. Receiver-operating characteristic curves were constructed to identify optimal discriminative cutoff values.
RESULTS: The mean β angle was significantly smaller in the 14 patients with negative results on AAD compared to the 24 patients with positive results on AAD (36 ± 20° vs. 62 ± 20°, p < 0.01). Its optimal cutoff value was 58°, which yielded a positive predictive value of 73% and a negative predictive value of 87% for conversion to type 1 pattern on AAD; α was slightly less sensitive and specific compared with β. When the angles were combined with QRS duration, it tended to improve discrimination.
CONCLUSIONS: In patients with suspected Brugada syndrome, simple ECG criteria can enable discrimination between incomplete RBBB and types 2 and 3 Brugada patterns.
PID Serval
serval:BIB_4A316CFDC50E
PMID
Open Access
Oui
Date de création
2011-12-27T16:15:42.445Z
Date de création dans IRIS
2025-05-20T20:51:08Z
Fichier(s)![Vignette d'image]()
En cours de chargement...
Nom
BIB_4A316CFDC50E.P001.pdf
Version du manuscrit
preprint
Taille
1.9 MB
Format
Adobe PDF
PID Serval
serval:BIB_4A316CFDC50E.P001
Somme de contrôle
(MD5):8956e6a2f51c3a5878d81f4a124a14db