  4. An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops.
 
  • Détails
Titre

An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
The International Journal of Artificial Organs  
Auteur(s)
Tozzi, P.
Auteure/Auteur
Maertens, A.
Auteure/Auteur
Emery, J.
Auteure/Auteur
Joseph, S.
Auteure/Auteur
Kirsch, M.
Auteure/Auteur
Avellan, F.
Auteure/Auteur
Liens vers les personnes
Tozzi, Piergiorgio  
Kirsch, Matthias  
Emery, Jonathan  
Joseph, Samuel  
Liens vers les unités
Chirurgie cardiaque  
ISSN
1724-6040
Statut éditorial
Publié
Date de publication
2017-11-24
Volume
40
Numéro
12
Première page
683
Dernière page/numéro d’article
689
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
We present the test bench results of a valveless total artificial heart that is potentially compatible with the pediatric population.
The RollingHeart is a valveless volumetric pump generating pulsatile flow. It consists of a single spherical cavity divided into 4 chambers by 2 rotating disks. The combined rotations of both disks produce changes in the volumes of the 4 cavities (suction and ejection). The blood enters/exits the spherical cavity through 4 openings that are symmetrical to the fixed rotation axis of the first disk.Mock circulatory system: The device pumps a 37% glycerin solution through 2 parallel circuits, simulating the pulmonary and systemic circulations. Flow rates are acquired with a magnetic inductive flowmeter, while pressure sensors collect pressure in the left and right outflow and inflow tracts.In vitro test protocol: The pump is run at speeds ranging from 20 to 180 ejections per minute. The waveform of the pressure generated at the inflow and outflow of the 4 chambers and the flow rate in the systemic circulation are measured.
At an ejection rate of 178 min-1, the RollingHeart pumps 5.3 L/min for a systemic maximal pressure gradient of 174 mmHg and a pulmonary maximal pressure gradient of 75 mmHg. The power input was 14 W, corresponding to an efficiency of 21%.
The RollingHeart represents a new approach in the domain of total artificial heart. This preliminary study endorses the feasibility of a single valveless device acting as a total artificial heart.
Sujets

Blood Circulation

Cardiovascular System...

Heart Failure/physiop...

Heart Failure/therapy...

Heart Transplantation...

Heart Transplantation...

Heart, Artificial

Humans

Mechanical Phenomena

Pulsatile Flow

PID Serval
serval:BIB_B73B0B254132
DOI
10.5301/ijao.5000634
PMID
28862717
WOS
000419640000005
Permalien
https://iris.unil.ch/handle/iris/135330
Date de création
2017-09-22T11:56:35.854Z
Date de création dans IRIS
2025-05-20T21:15:13Z
Fichier(s)
En cours de chargement...
Vignette d'image
Nom

ijao.5000634.pdf

Version du manuscrit

preprint

Taille

511.29 KB

Format

Adobe PDF

PID Serval

serval:BIB_B73B0B254132.P001

Somme de contrôle

(MD5):b6603b28fa49cf21757e0f7159226e32