• Mon espace de travail
  • Aide IRIS
  • Par Publication Par Personne Par Unité
    • English
    • Français
  • Se connecter
Logo du site

IRIS | Système d’Information de la Recherche Institutionnelle

  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
UNIL
  • English
  • Français
Se connecter
IRIS
  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
  • Mon espace de travail
  • Aide IRIS

Parcourir IRIS

  • Par Publication
  • Par Personne
  • Par Unité
  1. Accueil
  2. IRIS
  3. Publication
  4. Agreement between time-domain and spectral-domain optical coherence tomography in the assessment of macular thickness in patients with idiopathic macular telangiectasia type 2.
 
  • Détails
Titre

Agreement between time-domain and spectral-domain optical coherence tomography in the assessment of macular thickness in patients with idiopathic macular telangiectasia type 2.

Type
article
Institution
Externe
Périodique
Ophthalmologica: The European Retina Journal  
Auteur(s)
Mathew, R.
Auteure/Auteur
Sivaprasad, S.
Auteure/Auteur
Florea, D.
Auteure/Auteur
Leung, I.
Auteure/Auteur
Sallo, F.
Auteure/Auteur
Clemons, T.
Auteure/Auteur
Bird, A.C.
Auteure/Auteur
Peto, T.
Auteure/Auteur
Liens vers les personnes
Sallo, Ferenc Balazs  
ISSN
1423-0267
Statut éditorial
Publié
Date de publication
2013
Volume
230
Numéro
3
Première page
144
Dernière page/numéro d’article
150
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article ; Multicenter Study
Publication Status: ppublish
Résumé
To estimate the conversion factors to transpose macular thickness measurements on time-domain (TD) to various spectral-domain (SD) optical coherence tomography (OCT) machines in patients with macular telangiectasia type 2a (MacTel).
Macular scans on TD- and SD-OCT were performed on patients at the same visit. The retinal thickness values in various ETDRS subfields and macular volume were compared between different OCT machines.
The macular thickness and volume were significantly greater (p < 0.0001, r = 0.678-0.822) on SD-OCT. The mean differences in macular thickness between TD Stratus and SD-OCT by Spectralis, Cirrus and Topcon were 62, 41 and 20 μm, respectively. The conversion factor of macular thickness from TD-OCT to Spectralis, Cirrus and Topcon were +65, +39 and +25 μm, respectively.
The estimates of conversion of macular thickness from TD- to SD-OCT using simple mean differences between machines and those by linear regression were similar suggesting that the former may be used for the longitudinal follow-up of MacTel patients.
Sujets

Humans

Prospective Studies

Reproducibility of Re...

Retina/pathology

Retinal Telangiectasi...

Time Factors

Tomography, Optical C...

Tomography, Optical C...

PID Serval
serval:BIB_5C193D16F843
DOI
10.1159/000353455
PMID
23989133
WOS
000325421000007
Permalien
https://iris.unil.ch/handle/iris/37863
Date de création
2024-09-26T18:17:42.233Z
Date de création dans IRIS
2025-05-20T13:43:33Z
  • Copyright © 2024 UNIL
  • Informations légales