• Mon espace de travail
  • Aide IRIS
  • Par Publication Par Personne Par Unité
    • English
    • Français
  • Se connecter
Logo du site

IRIS | Système d’Information de la Recherche Institutionnelle

  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
UNIL
  • English
  • Français
Se connecter
IRIS
  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
  • Mon espace de travail
  • Aide IRIS

Parcourir IRIS

  • Par Publication
  • Par Personne
  • Par Unité
  1. Accueil
  2. IRIS
  3. Publication
  4. Cross-sectional compliance overestimates arterial compliance because it neglects the axial strain.
 
  • Détails
Titre

Cross-sectional compliance overestimates arterial compliance because it neglects the axial strain.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Swiss Medical Weekly  
Auteur(s)
Tozzi, P.
Auteure/Auteur
Hayoz, D.
Auteure/Auteur
Corno, A.F.
Auteure/Auteur
Mallabiabarrena, I.
Auteure/Auteur
von Segesser, L.K.
Auteure/Auteur
Liens vers les personnes
Hayoz, Daniel  
Tozzi, Piergiorgio  
Von Segesser, Ludwig Karl  
Liens vers les unités
Hypertension et médecine vasculaire  
Chirurgie cardiaque  
ISSN
1424-7860
Statut éditorial
Publié
Date de publication
2003-08-23
Volume
133
Numéro
33-34
Première page
461
Dernière page/numéro d’article
464
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
A high resolution echo-tracking system permits the calculation of cross-sectional compliance considering vessel diameter variations alone, and assumes that longitudinal movement of the vessel wall due to pulse pressure is negligible. However, using piezoelectric crystals sutured on the adventitia of the vessel wall we demonstrated that arterial length changes up to 5% (mean 2.7%) as a function of pulse pressure. Therefore, cross-sectional compliance seems to provide a limited approximation of the real phenomenon because it neglects axial vessel movement. Axial vessel movement is taken into account when the vessel compliance is calculated according to the principle of continuity of the mass: [equation: see text]. To verify this hypothesis we measured the blood flow gradient through 10 cm long segments of 10 pig carotid arteries (Qin - Qout) and divided it for the derivative of blood pressure over a given time (deltaP/deltat). For the same vessels, we calculated the cross-sectional compliance (CC) using the echo-tracking system (NIUS 02). We found a CC of (5.91 +/- 0.4) x 10(-7) micro m(2)/mm Hg and a segmental carotid compliance or dynamic compliance (C(d)) of (6.21 +/- 0.2) x 10(-8) micro m(3)/mm Hg. The impact of axial strain in calculations of compliance results in a dynamic compliance, which is one order of magnitude smaller than traditionally calculated arterial compliance.
Sujets

Animals

Blood Flow Velocity

Blood Pressure

Carotid Arteries/diag...

Carotid Arteries/phys...

Compliance

Data Interpretation, ...

Rheology/methods

Shear Strength

Swine

Ultrasonography

PID Serval
serval:BIB_1F03693AF779
DOI
10.4414/smw.2003.10287
PMID
14625813
WOS
000186472000003
Permalien
https://iris.unil.ch/handle/iris/44645
Date de création
2008-01-17T15:38:25.865Z
Date de création dans IRIS
2025-05-20T14:20:01Z
Fichier(s)
En cours de chargement...
Vignette d'image
Nom

14625813.pdf

Version du manuscrit

published

Taille

320.16 KB

Format

Adobe PDF

PID Serval

serval:BIB_1F03693AF779.P001

URN

urn:nbn:ch:serval-BIB_1F03693AF7797

Somme de contrôle

(MD5):9d2eb4c99ba402827e9f108b7545ebda

  • Copyright © 2024 UNIL
  • Informations légales