  4. Precision and accuracy of cross-sectional area measurements used to measure coronary endothelial function with spiral MRI.
 
  • Détails
Titre

Precision and accuracy of cross-sectional area measurements used to measure coronary endothelial function with spiral MRI.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Magnetic Resonance in Medicine  
Auteur(s)
Schär, M.
Auteure/Auteur
Soleimanifard, S.
Auteure/Auteur
Bonanno, G.
Auteure/Auteur
Yerly, J.
Auteure/Auteur
Hays, A.G.
Auteure/Auteur
Weiss, R.G.
Auteure/Auteur
Liens vers les unités
Radiodiagnostic & radiol. Interven.  
ISSN
1522-2594
Statut éditorial
Publié
Date de publication
2019-01
Volume
81
Numéro
1
Première page
291
Dernière page/numéro d’article
302
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, N.I.H., Extramural ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
Coronary endothelial function (CEF) reflects vascular health and conventional invasive CEF measures predict cardiovascular events. MRI can now noninvasively measure CEF by quantifying coronary artery cross-sectional area changes in response to isometric handgrip exercise, an endothelial-dependent stressor. Area changes (10 to 20% in healthy; 2 to -12% in impaired vessels) are only a few imaging voxels because of MRI's limited spatial resolution. Here, with numerical simulations and phantom studies, we test whether Fourier interpolation enables sub-pixel area measurement precision and determine the smallest detectable area change using spiral MRI.
In vivo coronary SNR with the currently used CEF protocol at 3T was measured in 7 subjects for subsequent in vitro work. Area measurements of circular vessels were simulated by varying partial volume, vessel diameter, voxel size, SNR, and Fourier interpolation factor. A phantom with precision-drilled holes (diameters 3-3.42 mm) was imaged 10 times with the current CEF protocol (voxel size, Δx = 0.89 mm) and a high-resolution protocol (Δx = 0.6 mm) to determine precision, accuracy, and the smallest detectable area changes.
In vivo coronary SNR ranged from 30-76. Eight-fold Fourier interpolation improved area measurement precision by a factor 6.5 and 4.9 in the simulations and phantom scans, respectively. The current CEF protocol can detect mean area changes of 4-5% for SNR above 30, and 3-3.5% for SNR above 40 with a higher-resolution protocol.
Current CEF spiral MRI with in vivo SNR allows detection of a 4-5% area change and Fourier interpolation improves precision several-fold to sub-voxel dimensions.
Sujets

Adult

Atherosclerosis/diagn...

Computer Simulation

Coronary Circulation

Coronary Vessels/diag...

Endothelium, Vascular...

Female

Fourier Analysis

Hand Strength

Humans

Magnetic Resonance Im...

Male

Middle Aged

Models, Theoretical

Phantoms, Imaging

Reproducibility of Re...

Signal-To-Noise Ratio...

Vasodilation

Fourier interpolation...

MRI

coronary endothelial ...

cross-sectional area ...

spiral

PID Serval
serval:BIB_70EE80048D23
DOI
10.1002/mrm.27384
PMID
30024061