• Mon espace de travail
  • Aide IRIS
  • Par Publication Par Personne Par Unité
    • English
    • Français
  • Se connecter
Logo du site

IRIS | Système d’Information de la Recherche Institutionnelle

  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
UNIL
  • English
  • Français
Se connecter
IRIS
  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
  • Mon espace de travail
  • Aide IRIS

Parcourir IRIS

  • Par Publication
  • Par Personne
  • Par Unité
  1. Accueil
  2. IRIS
  3. Publication
  4. Discrepancy between Visual Acuity and Microperimetry in AMD Patients: Visual Acuity Appears as an Inadequate Parameter to Test Macular Function.
 
  • Détails
Titre

Discrepancy between Visual Acuity and Microperimetry in AMD Patients: Visual Acuity Appears as an Inadequate Parameter to Test Macular Function.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Klinische Monatsblätter für Augenheilkunde  
Auteur(s)
Tran, B.K.
Auteure/Auteur
Herbort, C.P.
Auteure/Auteur
Liens vers les personnes
Herbort, Carl P  
Tran, Bao-Khanh  
Liens vers les unités
Hôpital ophtalmique Jules Gonin  
ISSN
1439-3999
Statut éditorial
Publié
Date de publication
2015
Volume
232
Numéro
4
Première page
529
Dernière page/numéro d’article
532
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal ArticlePublication Status: ppublish
Résumé
BACKGROUND: Best corrected visual acuity (BCVA) of 0.8 or above in AMD patients can sometimes correspond to poor macular function inducing a serious visual handicap. Microperimetry can be used to objectivize this difference.
PATIENTS AND METHODS: A retrospective study was undertaken on 233 files of AMD patients of whom 82 had had a microperimetry. BCVA was compared with microperimetry performance. All examinations were performed in an identical setting by the same team of 3 persons.
RESULTS: Among the 82 patients included, 32 (39.0%) had a BCVA equal to or above 0.8 even though their microperimetry performance was lower than 200/560 db. 10 of them (12.2% of total) had an even poorer microperimetry below 120/560 db indicating poor macular function.
CONCLUSIONS: More than a third of the AMD patients had a bad or very bad microperimetry performance in parallel with a good visual acuity. Microperimetry is a valuable tool to assess and follow real macular function in AMD patients when visual acuity alone can be misleading.
PID Serval
serval:BIB_C386ABE3D769
DOI
10.1055/s-0035-1545779
PMID
25902114
WOS
000353501000047
Permalien
https://iris.unil.ch/handle/iris/172300
Date de création
2015-08-31T14:18:38.235Z
Date de création dans IRIS
2025-05-21T00:18:16Z
  • Copyright © 2024 UNIL
  • Informations légales