• Mon espace de travail
  • Aide IRIS
  • Par Publication Par Personne Par Unité
    • English
    • Français
  • Se connecter
Logo du site

IRIS | Système d’Information de la Recherche Institutionnelle

  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
UNIL
  • English
  • Français
Se connecter
IRIS
  • Accueil
  • Personnes
  • Publications
  • Unités
  • Périodiques
  • Mon espace de travail
  • Aide IRIS

Parcourir IRIS

  • Par Publication
  • Par Personne
  • Par Unité
  1. Accueil
  2. IRIS
  3. Publication
  4. Trajectory correction enables free-running chemical shift encoded imaging for accurate cardiac proton-density fat fraction quantification at 3T.
 
  • Détails
Titre

Trajectory correction enables free-running chemical shift encoded imaging for accurate cardiac proton-density fat fraction quantification at 3T.

Type
article
Institution
UNIL/CHUV/Unisanté + institutions partenaires
Périodique
Journal of Cardiovascular Magnetic Resonance  
Auteur(s)
Daudé, P.
Auteure/Auteur
Troalen, T.
Auteure/Auteur
Mackowiak, ALC
Auteure/Auteur
Royer, E.
Auteure/Auteur
Piccini, D.
Auteure/Auteur
Yerly, J.
Auteure/Auteur
Pfeuffer, J.
Auteure/Auteur
Kober, F.
Auteure/Auteur
Gouny, S.C.
Auteure/Auteur
Bernard, M.
Auteure/Auteur
Stuber, M.
Auteure/Auteur
Bastiaansen, JAM
Auteure/Auteur
Rapacchi, S.
Auteure/Auteur
Liens vers les personnes
Stuber, Matthias  
Liens vers les unités
Radiodiagnostic & radiol. Interven.  
ISSN
1532-429X
Statut éditorial
Publié
Date de publication
2024
Volume
26
Numéro
2
Première page
101048
Peer-reviewed
Oui
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Metabolic diseases can negatively alter epicardial fat accumulation and composition, which can be probed using quantitative cardiac chemical shift encoded (CSE) cardiovascular magnetic resonance (CMR) by mapping proton-density fat fraction (PDFF). To obtain motion-resolved high-resolution PDFF maps, we proposed a free-running cardiac CSE-CMR framework at 3T. To employ faster bipolar readout gradients, a correction for gradient imperfections was added using the gradient impulse response function (GIRF) and evaluated on intermediate images and PDFF quantification.
Ten minutes free-running cardiac 3D radial CSE-CMR acquisitions were compared in vitro and in vivo at 3T. Monopolar and bipolar readout gradient schemes provided 8 echoes (TE1/ΔTE = 1.16/1.96 ms) and 13 echoes (TE1/ΔTE = 1.12/1.07 ms), respectively. Bipolar-gradient free-running cardiac fat and water images and PDFF maps were reconstructed with or without GIRF correction. PDFF values were evaluated in silico, in vitro on a fat/water phantom, and in vivo in 10 healthy volunteers and 3 diabetic patients.
In monopolar mode, fat-water swaps were demonstrated in silico and confirmed in vitro. Using bipolar readout gradients, PDFF quantification was reliable and accurate with GIRF correction with a mean bias of 0.03% in silico and 0.36% in vitro while it suffered from artifacts without correction, leading to a PDFF bias of 4.9% in vitro and swaps in vivo. Using bipolar readout gradients, in vivo PDFF of epicardial adipose tissue was significantly lower compared to subcutaneous fat (80.4 ± 7.1% vs 92.5 ± 4.3%, P < 0.0001).
Aiming for an accurate PDFF quantification, high-resolution free-running cardiac CSE-MRI imaging proved to benefit from bipolar echoes with k-space trajectory correction at 3T. This free-breathing acquisition framework enables to investigate epicardial adipose tissue PDFF in metabolic diseases.
Sujets

Humans

Predictive Value of T...

Phantoms, Imaging

Reproducibility of Re...

Male

Image Interpretation,...

Adipose Tissue/diagno...

Adult

Adiposity

Middle Aged

Female

Case-Control Studies

Protons

Magnetic Resonance Im...

Pericardium/diagnosti...

Aged

Computer Simulation

Magnetic Resonance Im...

Cardiac fat-water MRI...

Epicardial adipose ti...

Free-running MRI

Gradient impulse resp...

PID Serval
serval:BIB_0EFABD5B21A6
DOI
10.1016/j.jocmr.2024.101048
PMID
38878970
WOS
001273805200001
Permalien
https://iris.unil.ch/handle/iris/68200
Open Access
Oui
Date de création
2024-06-21T09:05:51.750Z
Date de création dans IRIS
2025-05-20T16:08:49Z
Fichier(s)
En cours de chargement...
Vignette d'image
Nom

38878970_BIB_0EFABD5B21A6.pdf

Version du manuscrit

published

Licence

https://creativecommons.org/licenses/by/4.0

Taille

14.88 MB

Format

Adobe PDF

PID Serval

serval:BIB_0EFABD5B21A6.P001

URN

urn:nbn:ch:serval-BIB_0EFABD5B21A66

Somme de contrôle

(MD5):d6e1d36b17f103e6e26989100183830a

  • Copyright © 2024 UNIL
  • Informations légales